Structure Design
Description
Double sheaths Aerial ADSS Cable For Long Span are specifically designed for use on overhead HV transmission and distribution lines with steel lattice towers or wooden, concrete or steel poles.
Application
1. Self-support Aerial installation;
2. Fiber-to-the-X networks;
3.Underground duct
Features
1. Stranded loose tube design ensures that the fibers are always free from mechanical strain under the specified loading conditions;
2. Double Jacket designs for medium to long span applications and moderate to heavy ice and wind loading conditions;
3. No metallic or conductive components, allowing the live-line installation (subject to local regulation)
4 Torsion ally-balanced aramid yarn strength elements provide stable cable design;
4. UV-resistant polyethylene sheath is compatible with fittings from all major suppliers and is suitable for use to 12kV space potential;
5. Custom designs for extremely long spans available Track-resistant options are also available for use up to 25kV space potential;
Standards
IEEE 1222, IEC 60794-4-20, ANSI/ICEA S-87-640, TELCORDIA GR-20, IEC 60793-1-22, IEC 60794-1-2, IEC 60794
Optical Fiber Characteristics
Parameters | Specification |
Optical Characteristics |
Fiber Type | G652.D |
Mode Field Diameter (um) | 1310nm | 9.1 ± 0.5 |
1550nm | 10.3 ± 0.7 |
Attenuation Coefficient (dB/km) | 1310nm | ≤ 0.35 |
1550nm | ≤ 0.21 |
Attenuation Non-uniformity (dB) | ≤ 0.05 |
Zero Dispersion Wavelength ( λ0) (nm) | 1300 ~ 1324 |
Max Zero Dispersion Slope (S0max) (ps/(nm2·km)) | ≤ 0.093 |
Polarization Mode Dispersion Coefficient (PMDQ) (ps/km1/2) | ≤ 0.2 |
Cut-off Wavelength (λcc) (nm) | ≤ 1260 |
Dispersion Coefficient (ps/ (nm·km)) | 1288~1339nm | ≤ 3.5 |
1550nm | ≤ 18 |
Effective Group Index of Refraction (Neff) | 1310nm | 1.466 |
1550nm | 1.467 |
Geometric characteristic |
Cladding Diameter (um) | 125.0 ± 1.0 |
Cladding Non-circularity (%) | ≤ 1.0 |
Coating Diameter (um) | 245.0 ± 10.0 |
Coating-cladding Concentrically Error (um) | ≤ 12.0 |
Coating Non-circularity (%) | ≤ 6.0 |
Core-cladding Concentrically Error (um) | ≤ 0.8 |
Mechanical characteristic |
Curling (m) | ≥ 4 |
Proof Stress (GPa) | ≥ 0.69 |
Coating Strip Force (N) | Average Value | 1.0 5.0 |
Peak Value | 1.3 ~ 8.9 |
Macro Bending Loss (dB) | Ф60mm, 100 Circles, @ 1550nm | ≤ 0.05 |
Ф32mm, 1 Circle, @ 1550nm | ≤ 0.05 |
Specifications
Parameters | Specification |
Fiber Count | 2 | 6 | 12 | 24 | 60 | 144 |
Loose Tube | Material | PBT |
Fibers per Tube | 2 | 4 | 4 | 4 | 12 | 12 |
Numbers | 1 | 2 | 3 | 6 | 5 | 12 |
Filler Rod | Numbers | 5 | 4 | 3 | 0 | 1 | 0 |
Central Strength Member | Material | FRP | FRP coated PE |
Water Blocking Material | Water blocking yarn |
Additional Strength Member | Aramid yarns |
Inner Jacket | Material | Black PE (Polythene) |
Thickness | Nominal: 0.8 mm |
Outer Jacket | Material | Black PE (Polythene) or AT |
Thickness | Nominal: 1.7 mm |
Cable Diameter (mm) | 11.4 | 11.4 | 11.4 | 11.4 | 12.3 | 17.8 |
Cable Weight (kg/km) | 94 ~ 101 | 94 ~ 101 | 94 ~ 101 | 94 ~ 101 | 119 ~ 127 | 241 ~ 252 |
Rated Tension Stress (RTS) (KN) | 5.25 | 5.25 | 5.25 | 5.25 | 7.25 | 14.5 |
Maximum Working Tension (40%RTS) (KN) | 2.1 | 2.1 | 2.1 | 2.1 | 2.9 | 5.8 |
Everyday Stress (15-25%RTS) (KN) | 0.78 ~ 1.31 | 0.78 ~ 1.31 | 0.78 ~ 1.31 | 0.78 ~ 1.31 | 1.08 ~ 1.81 | 2.17 ~ 3.62 |
Allowable Maximum Span (m) | 100 |
Crush Resistance (N/100mm) | Short time | 2200 |
Suiting Meteorological Condition | Max wind speed: 25m/s Max icing: 0mm |
Bending Radius (mm) | Installation | 20D |
Operation | 10D |
Attenuation (After Cable) (dB/km) | SM Fiber @1310nm | ≤ 0.36 |
SM Fiber @1550nm | ≤ 0.22 |
Temperature Range | Operation (℃) | -40 ~ +70 |
Installation (℃) | -10 ~ +50 |
Storage & Shipping (℃) | -40 ~ +60 |
Package